A gel and a titanium brush, used alone or together, have shown promise for removing the salivary protein layer from titanium surfaces that mimic dental implants, in laboratory research from the University of Oslo.

The work was an industrial PhD by chemical engineer Angela De Lauretis, a collaboration between the university’s Department of Biomaterials and Corticalis AS, with salary costs shared by Corticalis and the Research Council of Norway.

Biofilm plays a key role in peri-implant mucositis and peri-implantitis, and no single cleaning method has been shown to work best in every situation. As Ms De Lauretis put it, “there is no consensus within the professional community about which cleaning method works best”.

What was tested

Titanium discs with implant-like surfaces were coated with salivary proteins to form a pellicle. The team then tested a Poloxamer 407 hydrogel with and without hydrogen peroxide and a titanium brush, alone and in combination, and compared them with products on the market.

In a study published in ACS Biomaterials Science & Engineering, protein levels were similar across treatments, but each method left a distinct protein profile. Mechanical cleaning, alone or combined with the gel, improved protein removal, and combined treatments reduced the variety of proteins that readsorbed when surfaces were re-exposed to saliva. No treatment impaired stem cell adhesion or caused cytotoxicity.

The protein layer was not completely removed. A separate study found moist heat and electron-beam sterilisation preserved key properties of the gel.

The treatments have not been tested in patients, and the university says clinical studies are needed. Effects on bacterial deposits are being examined in other projects.

“No, we have not done that yet, but that is the goal,” Ms De Lauretis said of clinical testing.

Read the original study in ACS Biomaterials Science & Engineering.

Read the full study