Patients who received some of the world’s first single-tooth implants in the early 1980s remain highly satisfied with how they function almost four decades later, although their views on appearance vary widely.
The University of Gothenburg study, published in Clinical Implant Dentistry and Related Research, followed 13 patients with 18 single implants placed at the Brånemark Clinic in Gothenburg, Sweden, between 1982 and 1985. The mean follow-up was 38.9 years.
On 0–100 visual analogue scales, patients rated the overall treatment outcome at a mean of 92.8 and function at 95.5. Ease of oral hygiene around the implant crowns scored 90.2. Oral Health Impact Profile-14 scores pointed to a generally low impact on quality of life.
Aesthetics was a different story. Satisfaction with the appearance of the implant crowns averaged 80.9 but ranged from 7 to 100. Two prosthodontists scored peri-implant soft tissues using the Pink Esthetic Score, with means of 7.9 and 8.6 out of 14, though agreement between them was only limited to moderate.
Discrepancies in the anterior maxilla
In six maxillary central incisor sites, every implant crown sat out of line with the contralateral tooth at both the incisal edge and the gingival margin. Incisal discrepancies ranged from 1.04 to 2.47 mm and cervical discrepancies from 0.69 to 5.26 mm.
The largest cervical discrepancy was in a patient who received the implant at 14. The authors said this single case could not establish an age effect, but noted that implant placement at that age in the anterior maxilla would generally be considered premature today.
Because there were no baseline aesthetic measurements, the researchers could not say whether the discrepancies developed progressively over time.
“Teeth and surrounding tissues change throughout life, while implants remain fixed in the jawbone,” said co-author Sargon Barkarmo, a senior lecturer and specialist dentist at the university’s Sahlgrenska Academy.
The authors recommend delaying implants in growing patients where possible, telling patients positional discrepancies may still develop in adulthood, and favouring restorations that can be retrieved or replaced.
They cautioned that the cohort was small and that the machined-surface implants and early components differ substantially from those used today, so the results do not reflect contemporary treatment.
The same cohort was the subject of a 2025 report, which found all 18 implants still in function.
Read the study in Clinical Implant Dentistry and Related Research.